You can't hack the laws of physics. A Layer 1 data diode permanently closes the path from the network into your machines.
A data diode lets data travel one way only: from the machine network (OT) to the company network (IT). Try it on the drawing below: press HACK! or STOP on the IT side and turn the knob in OT. Not a single byte gets through the other way.
Attempts from IT to OT (STOP, HACK!) end in the RX module
i button: a description of the part on click
Fig. 1. Two MikroTik routers on separate plates, joined only by one fibre between the TX module (OT), which sends, and the RX module (IT), which receives. Motion is slowed down so you can follow the packets.
In a factory, a water utility or a heating plant, maintenance and management want to see machine data on the office network or in the cloud. Every such connection also opens a path the other way. One mistake in the firewall rules is enough for ransomware or a network-scanning AI bot to reach your controllers. Instead of stacking up more security software, we solve the problem physically. In a single fibre, light travels only from the site outwards.
We supply 1.25 Gbit/s SFP data diodes and build the whole telemetry chain: from the sensor on site to dashboards in Zabbix and Grafana or lightweight SCADA on Linux. Data from PLCs and from PCs running Windows XP, 7, MS-DOS or old Linux leaves the site, and no traffic comes back into the OT zone.
READ-ONLY TELEMETRY, NO CHANGES TO CONTROLWe read data and send it out one way. We do not change PLC programs or machine safety circuits, so the line builder's (OEM) warranty stays valid and production carries on unchanged.
OSI LAYER 1RT-DD-1G-10K-SM-TX / RX pair: one fibre, simplex LC, up to 10 km
LEGACY OS PROTECTIONMachines on Windows XP, 7, DOS and old Linux keep running, and no packet from the network reaches them
NO SUBSCRIPTIONA fraction of the price of conventional data diodes. The kit includes the SFP module pair, MikroTik hardware and commissioning help.
01 / CAPABILITIES
The whole telemetry chain: from field measurement to the operator's screen
We take data safely from the process (OT) and deliver it to supervision systems (IT or cloud). The Layer 1 diode makes sure that no signal from outside gets back to the site.
A hardware barrier at the OT/IT boundary that nobody can reconfigure remotely.
A pair of one-way 1.25 Gbit/s SFP transceivers (1310 nm, up to 10 km over a single 9/125 µm single-mode fibre, simplex LC). The RT-DD-1G-10K-SM-TX module on the OT side only transmits; the RT-DD-1G-10K-SM-RX on the IT side only receives. The fibre has no return path, so a network attack has no way to reach the site.
RT-DD-1G-10K-SM-TX
RT-DD-1G-10K-SM-RX
Layer 1 (OSI)
1.25 Gbit/s, simplex LC
IP65 versions
MODULE 02 // ELECTRONICS & DATA ACQUISITIONEDGE TELEMETRY
Measurement hardware and non-invasive data acquisition (IIoT)
We design our own measurement modules, so we can collect data even from machines with no communication interface.
We design electronics from schematic and PCB to finished module. We read data passively from brownfield machinery and industrial PCs running Windows XP, 7, MS-DOS or older Linux. We support Modbus RTU/TCP, OPC UA, MQTT, SNMP and raw TCP/UDP frames, and wirelessly LoRaWAN, LTE-M/NB-IoT, Wi-Fi and BLE.
We protect systems that can no longer be updated, and help you meet NIS2 requirements.
In industry, many machines must keep running on software that no longer gets patches. Instead of exposing them behind a software firewall or VLAN, we cut them off physically with an SFP data diode (also in IP65 enclosures). Distributed sites get encrypted site-to-site VPNs (WireGuard, IPsec, OpenVPN) in line with IEC 62443 and the NIS2 Directive.
Maintenance sees trends on dashboards and gets alerts in real time.
We turn raw telemetry into information for maintenance and management. We deploy Zabbix for continuous monitoring and alerts (SMS, email, messengers), build Grafana dashboards and lightweight browser-based SCADA on Linux. You pay no licence fee per data point (0 EUR per tag).
Zabbix Monitoring
Grafana Dashboards
Web SCADA (Linux)
On-Premise / Cloud
02 / PRODUCT: LAYER 1 DATA DIODE
1.25 Gbit/s SFP hardware data diode: RT-DD-1G-10K-SM-TX / RX
We moved network isolation down to the physical layer, into a standard SFP (MSA) module. The direction of transmission comes from how the optical path is built, so no configuration change can reverse it.
GUARANTEED BY PHYSICS // OSI LAYER 1 HARDWARE SECURITY
Protection against AI bots, ransomware, zero-day exploits and APT attacks
AI bots scanning the network, ransomware, unknown zero-day flaws in network devices and long-running APT campaigns all need a path to their target to deliver a payload or a command. In the diode's single fibre, light travels only from the OT site outwards, so that path does not exist. No packet from the network can reach your PLCs or legacy systems (Windows XP, 7, DOS, old Linux) over this link. The protection comes from the physics of the optical path, so it needs no updates.
OT SIDE MODULE (SITE, PROTECTED ZONE)
RT-DD-1G-10K-SM-TX
Goes into the protected industrial network (OT). It sends a one-way 1.25 Gbit/s stream (1310 nm) into a single simplex LC fibre and physically cannot receive any packet from outside.
IT SIDE MODULE (SERVER, DMZ, CLOUD)
RT-DD-1G-10K-SM-RX
Goes into the external network, the DMZ or next to the monitoring server. It receives the 1310 nm stream from the single simplex LC fibre and physically cannot send any signal back into the OT zone.
STARTER KIT WITH MIKROTIK // ONE-TIME PURCHASE
Complete starter kit: SFP diodes, MikroTik hardware and commissioning help
It costs a fraction of a conventional data diode, which often comes with an expensive service contract. The kit includes the RT-DD-1G-10K-SM-TX and RT-DD-1G-10K-SM-RX pair, MikroTik hardware and basic commissioning support. You pay once, with no subscription. We also sell the SFP pairs on their own.
Our demo kit is ready to go. We will show you live that data flows one way only, and test your own case: PLCs, machines on Windows XP, 7 or DOS, Modbus, OPC UA or MQTT, and visualisation in Zabbix and Grafana.
Software (802.1Q VLAN tags and filtering rules in the firewall)
Physics (the simplex LC fibre has no optical return path)
Resistance to AI bots, zero-day exploits & APT
Limited. A configuration error, a firmware flaw or a stolen admin account is enough
Independent of software. There is no return channel, so nobody can open one remotely
Protection of unsupported systems (Windows XP, 7, DOS, old Linux)
High risk. Any open port or wrong rule exposes the system to attacks that will never be patched
The legacy system only sends telemetry out, and no packet from the IT network reaches it
Throughput & distance
Limited by packet inspection; usually up to 100 m over copper
Full 1.25 Gbit/s over one 9/125 µm single-mode fibre, up to 10 km
Running costs (TCO)
Yearly UTM licences, constant updates and rule audits (and conventional data diodes cost many times more)
One-time purchase, no subscription, at a fraction of the price of conventional data diodes. Available as a starter kit with MikroTik hardware and commissioning help
FULL SPECIFICATION (1.25 Gbit/s · 1310 nm · simplex LC, 10 km · SFF-8472 DDM · 3.3 V · −40…+85 °C):Open the datasheet →
03 / WHO WE WORK FOR
Where a data diode and telemetry solve a specific problem
We work for companies and public operators across Europe that need live process data and cannot risk downtime or a cyberattack.
UTILITIES & ENERGY (NIS2)
Water and wastewater utilities, district heating, treatment plants, biogas
Challenge: NIS2 requires effective protection of OT systems against attacks from the office network and the internet. Control rooms and billing still need readings around the clock.
RUTKOWSKI.TECH solution:We cut the site off physically with an SFP data diode and set up Zabbix and Grafana on the IT side with live readings.
MANUFACTURING & UNSUPPORTED SYSTEMS (XP / 7 / DOS)
Machines running old software (Windows XP, 7, MS-DOS, old Linux)
Challenge: production lines, CNC machines and test benches often have to run Windows XP, 7, MS-DOS or an old Linux kernel. Connected to the company network, they would be exposed to attacks that will never be patched.
RUTKOWSKI.TECH solution:The data diode cuts the machine off from all incoming traffic. The old system keeps running unchanged, and its data flows one way to Grafana and Zabbix.
PARTNERSHIP FOR AUTOMATION INTEGRATORS
Automation integrators and machine builders (OEM)
Challenge: your team programs the PLCs, but the end customer's specification calls for a hardware data diode, NIS2 compliance, MQTT/Zabbix telemetry or custom electronics.
RUTKOWSKI.TECH solution:We join as your telemetry and Layer 1 subcontractor. We do not program PLCs, so we never compete with you for the customer. We supply SFP diodes, measurement electronics and monitoring.
DISTRIBUTED SITES & COLD CHAIN
Cold stores (HACCP), grain silos, pumping stations and remote sites
Challenge: long distances (up to 10 km of fibre, or wireless), harsh conditions (IP65) and a duty to log temperatures and pressures continuously.
RUTKOWSKI.TECH solution:LoRaWAN / NB-IoT sensor networks and fibre links of up to 10 km behind SFP diodes, with automatic reports and SMS / email alerts.
04 / BOTTOM-UP ARCHITECTURE
Four telemetry layers: from the site (OT) up to supervision and cloud (IT)
Data flows upwards only. Machines and sensors at the bottom produce measurements that pass through the Layer 1 hardware barrier to the analytics systems.
STAGE 01 // BOTTOM (OT)
Field level, OT (bottom)
Non-invasive measurement of physical quantities and passive readout of PLC registers and PCs running old software (Windows XP/7, DOS, Linux).
4–20 mA · PT100 · PLC · Win XP/7/DOS
STAGE 02 // EDGE
Edge conversion & aggregation
Our modules translate industrial protocols into one telemetry stream, ready to send upwards.
Modbus · OPC UA · MQTT · LoRaWAN
STAGE 03 // LAYER 1 (SFP)
SFP diode (Layer 1)
The RT-DD-1G-10K-SM-TX module (OT) sends data as 1310 nm light over one simplex LC fibre to the RT-DD-1G-10K-SM-RX (IT). Nothing flows the other way.
Common questions on engineering, deployment and NIS2 audits
Straight answers for maintenance managers, automation engineers and security leads (CISOs).
What is a data diode?
A data diode (also called a unidirectional gateway) is a network device that sends data in one direction only. According to NIST SP 800-82 Rev. 3 (2023), unlike a firewall it cannot be programmed to let data flow both ways, because the hardware is incapable of it. It usually sits at the boundary between the OT and IT networks: data leaves the site, and nothing from outside gets in. RT-DD-1G is a data diode built as a pair of SFP modules.
How does a hardware SFP data diode protect an OT network from outside attacks?
A remote attack, whether run by an AI bot, a ransomware group or an APT team with a zero-day, works in the software layers (2–7) and needs a path to the target device. The RT-DD-1G-10K-SM-TX (OT side) and RT-DD-1G-10K-SM-RX (IT side) pair works at Layer 1. Joined by one simplex LC fibre, it carries light only from the site outwards. With no return path, no packet from the internet or the office network can reach the PLCs that way. The diode protects the site like this as long as it is the only connection between the zones.
How do you secure machines running legacy software (Windows XP, Windows 7, MS-DOS, old Linux) that must stay in operation?
In many plants, special machines, process lines and HMI stations must run unsupported operating systems (Windows XP, 7, MS-DOS, older Linux), because replacing the control system would cost hundreds of thousands of euros or is technically impossible. Microsoft ended support for Windows XP on 8 April 2014 and for Windows 7 on 14 January 2020 (paid ESU updates ran until January 2023), so new flaws in these systems are no longer patched. An SFP data diode cuts such a system off from all incoming traffic from the IT network. The system keeps sending production reports and telemetry, and flaws that nobody will ever patch can no longer be reached from the network.
Does a data diode help meet NIS2 requirements?
Yes, as one of the technical measures, but not on its own. EU Member States had to transpose the NIS2 Directive (EU) 2022/2555 by 17 October 2024. Article 21 requires risk-management measures for network and information systems, and Article 34 sets the maximum fines at no less than EUR 10 million or 2% of worldwide annual turnover, whichever is higher, for essential entities, and EUR 7 million or 1.4% for important entities. A data diode separates OT from IT physically, which is easy to show in an audit. Risk analysis, procedures and incident reporting have to be covered separately.
What is the difference between RT-DD-1G-10K-SM-TX and RT-DD-1G-10K-SM-RX?
They are matching 1.25 Gbit/s SFP transceivers (SFP MSA and SFF-8472 DDM compliant) for one 9/125 µm single-mode fibre: simplex LC connector, 1310 nm wavelength, up to 10 km. The RT-DD-1G-10K-SM-TX goes on the protected (OT) side and only transmits. The RT-DD-1G-10K-SM-RX goes on the IT, cloud or DMZ side and only receives.
How is an SFP data diode different from a 19-inch rack data diode?
A conventional data diode is usually a separate 19-inch rack appliance with its own software, often with a paid service contract. The RT-DD-1G SFP data diode is a pair of modules that you install in the SFP slots of routers or switches on each side of the boundary. The optical path alone makes it one-way, and software on a router or edge server carries the protocols (MQTT, Modbus, OPC UA). Such a kit costs a fraction of a conventional data diode and needs no subscription.
How do Modbus TCP, OPC UA or MQTT data cross a one-way SFP data diode?
In front of the RT-DD-1G-10K-SM-TX module, inside the OT zone, an edge module (telemetry proxy) polls PLCs and older PCs over Modbus RTU/TCP, OPC UA or SMB/CSV, or receives MQTT and SNMP data. It turns the readings into a one-way UDP stream and sends it over the 1.25 Gbit/s optical link. Behind the RT-DD-1G-10K-SM-RX, a server rebuilds the data and stores it in Zabbix, Grafana or the cloud.
Does your telemetry require changes to PLC programs, or put the machine warranty at risk?
No. We work on telemetry only, never on control. We do not change PLC logic or machine safety circuits. We read data passively from existing interfaces or from our own non-invasive measurement modules, such as split-core current transformers, temperature and pressure sensors or opto-isolated inputs.
Which regions do you cover, and do you take on clients from across Europe?
Yes. We deliver hardware and projects across Europe: Poland, the DACH countries (Germany, Austria, Switzerland), the rest of the EU, Scandinavia and the United Kingdom. From our base near Poznań, Poland, we ship configured SFP data diode kits and measurement electronics.
ADDRESS
RUTKOWSKI.TECH — Michał Rutkowski Gaj Mały 113d, 64-520 Obrzycko (Greater Poland, Poland, EU)
ORDERS, LIVE DEMOS & TELEMETRY PROJECTS (ALL OF EUROPE)
Starter kit, live demo or a quote